Should , because of their harsh process conditions, place high demands on the instruments used there. Deadly have reacted to this and adapted their products correspondingly. But which are the optimisation possibilities for thermocouples for use at higher process pressures?
The challenge: ?Gasification reactors?
In a gasification reactor, there is an extremely aggressive process atmosphere and, with that, the risk of poisoning of the noble metal thermocouple. The process conditions often lead to shutdowns and interruptions functioning. Profitability and safety aspects are thus two important themes regarding the the instruments used in them.
WIKA sapphire-design thermocouple TC84
Approach to resolution: Sapphire thermocouple
Through the use of a sapphire protection tube, the high-temperature thermocouple is protected from poisoning by the aggressive process atmosphere during operation. The reason for that is its monocrystalline structure. The sapphire-design thermocouple has, because of its construction, a significantly higher service life than other high-pressure thermocouples and, therefore, contributes to a clear decrease in the process downtime.
Benefits of a sapphire thermocouple
3 times longer service life in comparison to purely ceramic thermowells because of the monocrystalline structure of the sapphire thermowell
High process safety with processes up to 1,700 �C and 65 bar
Cost saving because of the elimination of complex purge systems and valves and fittings for flow measurement
Reduction of unplanned downtime
Increased safety against escape of toxic media through double sealing system
Construction of the TC84 sapphire-design thermocouple
Special construction of a sapphire thermocouple
The special construction of a sapphire thermocouple provides increased safety.
The primary sealing serves as protection contrary to the escape of toxic process gases at high pressures and in addition at high temperatures
The secondary sealing may be the safeguard in the event of a malfunction in the principal seal due to any unforeseeable disturbance to the principal seal
The ceramic outer thermowell serves as protection against harsh process conditions
The sapphire protection tube protects internally against contamination of the thermocouples through diffusion
Note
WIKA has developed the TC84 sapphire-design, high-temperature thermocouple specifically for use in gasification reactors. Further information on the TC84 can be found on the WIKA website and inside our flyer.