Temperature switches in machine building: Which type suits?

Temperature switches are used in machine building and other industrial applications for limiting temperature. They monitor the temperature and react at a predefined point. To protect from Scandal switch the gear or machine off or switch on a fan for cooling. Depending on task at hand, temperature switches operate as either normally-closed or normally-open switches. Three switch types are believed for industrial applications:
Electronic switches
Example: Electrical WIKA temperature switch TSD-30
Where a higher accuracy is requested, the operator should resort to an electronic switch. With this particular instrument, it is possible to change the limit values yourself and set several switch points. Electronic temperature switches can be utilized beyond their actual function ? yet another analogue output (e.g. 4 ? 20 mA) enables further processing of the signal and thus continuous temperature monitoring as well.
Furthermore, switches of the type can be fitted with digital communication (IO-Link). Bonanza of these are an even faster parametrisation alongside extended diagnostics functions and integration into automated processes. Via an LED display, an on-site indication may also be provided.
The wide usability of the electronics is reflected in the purchase costs. It also sets limits on the operating temperature. Its maximum value is, on average,150 �C, which is sufficient in most of applications, however. As a way to fulfil their tasks, electronic temperature switches need, in addition to a power source, an additional contactor since their transistor only switches suprisingly low power.
Dial thermometers with switch contact
Example: WIKA expansion thermometer with switch contact SB15
The outstanding feature of dial thermometers with switch contacts is the wide temperature range. In general, expansion thermometers are employed for industrial applications. They cover ? with respect to the version ? temperatures up to 400�C.
This instrument type offers the operator the possibility of selecting multiple switch points and setting them independently. Additionally it is suitable for switching in the low-voltage range (250 VAC). Yet another contactor isn’t needed. Dial thermometers with switch contacts function without additional power and, furthermore, offer an on-site display. An additional processing of the signal isn’t possible, however.
With regard to price and performance, the switch solution described here’s situated in the mid range.
Bimetal temperature switch
Example: WIKA bimetal temperature switch model TFS35
Bimetal temperature switches have become compact, cost-effective and also have been designed for a wide range of applications. These instruments can also switch with low voltages around 250 VAC, and with this they can manage with no additional contactor.
Bimetal temperature switches operate with lower accuracy. Working exclusively as switches, they neither provide a local display, nor do they enable any processing of the signal. Their compact design also only permits a restricted temperature range (max. 200 �C), since the plug connection is quite near to the hot area.
Note
More info on the TSD-30 electronic switch, on the SB15 dial thermometer with switch contact and on the TFS35 bimetal temperature switch are available on the WIKA website.
Also read our articles
Overview: How does the IO-Link work?
Safety temperature limiter for plants safe to use

Leave a Comment